Concept Guide

MIB Support for Power Monitoring
Dell EMC Networking provides MIB objects to display the information for Power Monitoring. The OIDs specic to Power Monitoring are
appended to the DellITaMIbs. There are three separate DellITaMIbs available to display the current input power, average input power and
average input-power start time. These statistics can also be obtained by using the CLI command:
show environment
. The following table
lists the related MIB objects, OID and description for the same:
Table 112. MIB Objects to Display the Information for Power Monitoring
MIB Object OID Description
envMonSupplyCurrentPower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5 Displays per PSU input power (current
conguration).
envMonSupplyAveragePower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6 Displays average input power.
envMonSupplyAvgStartTime 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7 Displays average input-power start time.
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support to Display the Available Memory Size on
Flash
Dell EMC Networking provides more MIB objects to display the available memory size on ash memory. The following table lists the MIB
object that contains the available memory size on ash memory.
Table 113. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object OID Description
chStackUnitFlashUsageUtil 1.3.6.1.4.1.6027.3.10.1.2.9.1.6 Contains ash memory usage in percentage.
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the ash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.
Viewing the Available Flash Memory Size
To view the available ash memory using SNMP, use the following command.
snmpget -v2c -c public 192.168.60.120 .1.3.6.1.4.1.6027.3.10.1.2.9.1.6.1
enterprises.6027.3.10.1.2.9.1.5.1 = Gauge32: 24
The output above displays that 24% of the ash memory is used.
966
Simple Network Management Protocol (SNMP)