Connectivity Guide

show alarms details
Displays details about active alarms.
Syntax
show alarms details
Parameters None
Default None
Command Mode EXEC
Usage Information None
Example
OS10# show alarms details
Active-alarm details - 1
-------------------------------------------
Sequence Number: 3
Severity: major
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time:
State: raised
-------------------------------------------
Active-alarm details - 2
-------------------------------------------
Sequence Number: 4
Severity: minor
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------
Supported Releases 10.2.0E or later
show alarms history
Displays the history of all alarm events.
Syntax
show alarms history [summary]
Parameters summary — Enter to view a summary of the alarm history.
Default None
Command Mode EXEC
Usage Information None
Example
OS10# show alarms history
Sq No State Name Timestamp Source
----- -------- ------------------ ----------------------- ------
1 Stateless SYSTEM_REBOOT Sun 10-07-2018 15:39:47
2 Raised EQM_FANTRAY_FAULT Sun 10-07-2018 16:39:47 /fantray/3
3 Raised EQM_MORE_PSU_FAULT Sun 10-07-2018 18:39:47 /psu/2
4 Raised EQM_MORE_PSU_FAULT Sun 10-07-2018 18:39:47 /psu/1
Troubleshoot OS10 1189