Connectivity Guide

Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example (Minor)
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number: 4
Severity: minor
Type: 1081375
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------
Supported Releases 10.4.3 or later
show alarms summary
Displays the summary of all active alarms.
Syntax
show alarms summary
Parameters None
Default Not congured
Command Mode EXEC
Usage Information None
Example
OS10# show alarms summary
Active-alarm Summary
-------------------------------------------
Total-count: 2
Critical-count: 0
Major-count: 1
Minor-count: 1
Warning-count: 0
-------------------------------------------
Supported Releases 10.2.0E or later
Logging commands
clear logging
Clears messages in the logging buer.
Syntax
clear logging log-file
Parameters None
Default Not congured
1192 Troubleshoot OS10