Connectivity Guide
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example (Minor)
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number: 4
Severity: minor
Type: 1081375
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------
Supported Releases 10.4.3 or later
show alarms summary
Displays the summary of all active alarms.
Syntax
show alarms summary
Parameters None
Default Not congured
Command Mode EXEC
Usage Information None
Example
OS10# show alarms summary
Active-alarm Summary
-------------------------------------------
Total-count: 2
Critical-count: 0
Major-count: 1
Minor-count: 1
Warning-count: 0
-------------------------------------------
Supported Releases 10.2.0E or later
Logging commands
clear logging
Clears messages in the logging buer.
Syntax
clear logging log-file
Parameters None
Default Not congured
1192 Troubleshoot OS10