The following shows BUM trac replication in the controller-provisioned VXLAN environment:
Since VTEP relies on service nodes to replicate BUM trac, we need a mechanism to monitor the connectivity between the VTEP and the
service nodes. BFD can be used monitors the connectivity between the VTEP and service nodes, and detects failures. The NSX controller
provides parameters, such as the minimum TX and RX interval, and the multiplier, to initiate the BFD session between the VTEP and the
service nodes. To establish a BFD session, enable the BFD on both the controller and the VTEP. To enable BFD in the VTEP, use bfd
enable command.
NOTE
: In controller-provisioned VXLAN, the VTEP establishes a BFD session with the service nodes using the controller-
provided parameters instead of the parameters congured at the VTEP.
If BFD is not enabled in the VTEP, the VTEP uses IP reachability information to monitor connectivity to the service node.
To view established sessions, use the show bfd neighbors command.
OS10# show bfd neighbors
* - Active session role
------------------------------------------------------------------------------------------
LocalAddr RemoteAddr Interface State RxInt TxInt Mult VRF Clients
------------------------------------------------------------------------------------------
* 55.55.5.5 2.2.2.2 virtual-network0 up 1000 1000 3 default vxlan
* 55.55.5.5 2.2.2.3 virtual-network0 up 1000 1000 3 default vxlan
View replicators
To view the state of the replicators, use the show nve replicators command.
Show output with details about the replicators received from the controller.
OS10# show nve replicators
Codes: * - Active Replicator
BFD Status:Enabled