Service Manual

Version Description
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
Example (Index)
Dell(conf)# rmon event 111 -> Default case
Dell(conf)# rmon event 112 log -> Only “log” option
Dell(conf)# rmon event 113 trap private -> Only “trap” option
Dell(conf)# rmon event 114 log trap public-> Both “log” and “trap” options
Dell(conf)#do show rmon events
RMON event entry 111
description:
event type: none.
event community:
event last time sent: none
event owner:
event status: OK
RMON event entry 112
description:
event type: LOG.
event community:
event last time sent: none
event owner:
event status: OK
RMON event entry 113
description:
event type: SNMP TRAP.
event community: private
event last time sent: none
event owner:
event status: OK
RMON event entry 114
description:
event type: LOG and SNMP TRAP.
event community: public
event last time sent: none
event owner:
event status: OK
Example (Brief)
Dell# show rmon event brief
index description
------------------------------
1 1
2 2
3 3
4 4
5 5
6 6
7 7
1354 Remote Monitoring (RMON)