Usage Information This command sets the counter polling interval for an interface.
Related Commands
sow polling-interval (Global) — globally sets the polling interval.
sow sample-rate (Global)
Change the global default sampling rate.
Syntax
sflow sample-rate value
To return to the default sampling rate, use the no sflow sample-rate command.
Parameters
value Enter the sampling rate value. For the C-Series and S-Series, the range is from 256 to
8388608 packets Enter values in powers of 2 only; for example, 4096, 8192, 16384, and
so on. The default is 32768 packets.
Defaults 32768 packets
Command Modes CONFIGURATION