Service Manual

ecfmNotication of changes to ECFM.
ecmp — Enable an ECMP trap to notify of ECMP or link bundle trac imbalances.
envmon — For Dell Networking device notications when an environmental
threshold is exceeded.
isisNotication of intermediate service traps.
lacpNotication of changes.
snmpNotication of RFC 1157 traps.
stpNotication of a state change in the spanning tree protocol (RFC 1493).
vltNotication of virtual link trunking.
vrrpNotication of a state change in a VRRP group.
xstpNotication of a state change in MSTP (802.1s), RSTP (802.1w), and PVST
+.
notication-option For the envmon notication-type, enter one of the following optional parameters:
cam-utilization
fan
supply
temperature
For the snmp notication-type, enter one of the following optional parameters:
authentication
coldstart
linkdown
linkup
syslog-reachable
syslog-unreachable
Defaults Not enabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.8(0.0) Added the following two SNMP notication options: syslog-reachable and
syslog-unreachable.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux
(PMUX) mode only.
9.0.2.0 Introduced on the S6000.
Simple Network Management Protocol (SNMP) and Syslog 1495