monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the trac that you
want to monitor and the ACL in which you are creating the rule is applied to the
monitored interface.
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is ve minutes. By default, ow-based monitoring is not
enabled.
Command Modes CONFIGURATION-STANDARD-ACCESS-LIST
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000–ON.
9.4(0.0) Added support for ow-based monitoring on the S4810, S4820T, S6000, and Z9000
platforms.
9.3(0.0) Added support for logging of ACLs on the S4810, S4820T, and Z9000 platforms.
Usage Information
When the congured maximum threshold is exceeded, generation of logs is stopped. When the interval at which
ACL logs are congured to be recorded expires, the subsequent, fresh interval timer is started and the packet
count for that new interval commences from zero. If ACL logging was stopped previously because the congured
threshold is exceeded, it is re-enabled for this new interval.
If ACL logging is stopped because the congured threshold is exceeded, it is re-enabled after the logging interval
period elapses. ACL logging is supported for standard and extended IPv4 ACLs, IPv6 ACLs, and MAC ACLs. You
can congure ACL logging only on ACLs that are applied to ingress interfaces; you cannot enable logging for ACLs
that are associated with egress interfaces.
You can activate ow-based monitoring for a monitoring session by entering theflow-based enable command
in the Monitor Session mode. When you enable this capability, trac with particular ows that are traversing
through the ingress and egress interfaces are examined and, appropriate ACLs can be applied in both the ingress
and egress direction. Flow-based monitoring conserves bandwidth by monitoring only specied trac instead all
trac on the interface. This feature is particularly useful when looking for malicious trac. It is available for Layer 2
and Layer 3 ingress and egress trac. You may specify trac using standard or extended access-lists. This
mechanism copies all incoming or outgoing packets on one port and forwards (mirrors) them to another port. The
source port is the monitored port (MD) and the destination port is the monitoring port (MG).
permit udp (for Extended IP ACLs)
To pass UDP packets meeting the lter criteria, congure a lter.
Syntax
permit udp {source mask | any | host ip-address} [operator port [port]]
{destination mask | any | host ip-address} [dscp] [operator port [port]] [count
[byte]] [order] [fragments] [log [interval minutes] [threshold-in-msgs [count]]
[monitor]
Access Control Lists (ACL) 289