Service Manual

Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Replacement command for the S4820T. Replaces the enable xfp-power-updates
command.
8.3.11.4 Replacement command for the Z9000. Replaces the enable xfp-power-updates
command
8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-power-
updates command.
Usage Information To enable polling and to congure the polling frequency, use this command.
enable xfp-power-updates
Enable 10–gigabit small form-factor pluggable (XFP) power updates for SNMP.
Syntax
enable xfp-power-updates interval seconds
Parameters
interval seconds Enter the keyword interval then the polling interval in seconds. The range is from 120
to 6000 seconds. Default: 300 seconds (5 minutes).
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
8.3.19.0 Deprecated command for S4820T. Replaced by the enable optic-info-update
interval command to update information on temperature and power monitoring in the
SNMP MIB.
8.3.11.4 Deprecated command for Z9000. Replaced by the enable optic-info-update
interval command to update information on temperature and power monitoring in the
SNMP MIB.
8.3.10.0 Deprecated command for the S4810 only. Replaced by the enable optic-info-
update interval command to update information on temperature and power
monitoring in the SNMP MIB.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series and E-Series.
Usage Information The chassis MIB contains the entry chSysXfpRecvPower in the chSysPortTable table. Periodically, IFA polls
the XFP power for each of the ports and sends the values to IFM where it is cached.
98 Control and Monitoring