vxlan-instance instance ID {nsx | Nuage}
Use the nsx keyword to connect to an NSX controller. Use the nuage keyword to connect to a Nuage controller. NSX is the default
value.
3 Dene how the device connects to the controller.
VxLAN INSTANCE mode
controller controller ID ip address port port-number TCP | SSL
The port number range is from 1 to 6632. The default connection type is SSL. TCP, PTCP, and PSSL are supported with NSX
controller only.
4 Enter the gateway IP
VxLAN INSTANCE mode
gateway-ip IP address
5 Enter the maximum backo time (Optional).
VxLAN INSTANCE mode
max_backoff time
The range is from 1000-180000. The default value is 30000 milliseconds.
6 Enter the fail mode (Optional).
VxLAN INSTANCE mode
fail-mode secure
Dell EMC Networking recommends non-secure mode for an NSX controller-based VXLAN in a VLT setup.
7 Enable the VXLAN instance.
VxLAN INSTANCE mode
no shutdown
Advertising VXLAN Access Ports to Controller
To advertise the access ports to the controller, use the following command.
In INTERFACE mode, vxlan-instance command congures a VXLAN-Access Port into a VXLAN-instance.
INTERFACE mode
vxlan-instance
Displaying VXLAN Congurations
To display the VXLAN congurations, use the following commands.
Examples of the show vxlan-instance Command
The following example shows the show vxlan vxlan-instance command.
DellEMC#show vxlan vxlan-instance 1
Instance : 1
Mode : Controller
Admin State : enabled
Controller Type : Nsx
Management IP : 10.16.140.34
Gateway IP : 4.3.3.3
MAX Backoff : 8000
Virtual Extensible LAN (VXLAN)