Users Guide

Add the keyword secondary if the IP address is the interface’s backup IP address.
Example of the show ip interface Command
You can only congure one primary IP address per interface. You can congure up to 255 secondary IP addresses on a single interface.
To view all interfaces to see with an IP address assigned, use the show ip interfaces brief command in EXEC mode as shown in
View Basic Interface Information.
To view IP information on an interface in Layer 3 mode, use the show ip interface command in EXEC Privilege mode.
DellEMC>show ip interface vlan 58
Vlan 58 is up, line protocol is up
Internet address is 1.1.49.1/24
Broadcast address is 1.1.49.255
Address determined by config file
MTU is 1554 bytes
Inbound access list is not set
Proxy ARP is enabled
Split Horizon is enabled
Poison Reverse is disabled
ICMP redirects are not sent
ICMP unreachables are not sent
IP unicast RPF check is not supported
Monitoring internal physical temperature of 10GBase-
T optical ports
The Dell EMC Networking OS monitors the internal physical temperature for all 10GBase-T optical ports. If the temperature of the optical
port reaches beyond the threshold, which is 104 degrees in Celsius, the optical port is reset automatically.
To monitor the internal temperature of the optical ports, execute the enable stack-unit unit-number port port-number
phy temp polling command.
When the temperature reaches more than 104 degrees in Celsius, the corresponding optical port is reset automatically and the system
generates the following syslog warning and major alarm.
IFAGT-5-PHY_TEMP_THOLD_REACH: 10GBaseT port 1/2 will get in to reset mode, transceiver
internal phy current temperature is 117 C.
To view the programmed alarm, use the show alarms command.
DellEMC#show alarms
Alarm Type Duration
-------------------------------------------------------------------------------
Controlling Bridge:
==================
Minor Alarms
No minor alarms
Major Alarms
Port 2 in unit 1 high internal temperature 1 min, 33 sec
NOTE
: This feature is not supported for stacking ports.
To change the optical port from reset to normal mode, you must execute the enable stack-unit unit-number port port-
number
transceiver command.
Example of the show command outputs
To view if this feature is enabled or disable, use the show interface interface-name transceiver command. The output also
displays the internal temperature of the optical ports, when the physical temperature polling is enabled. If the temperature polling is
disabled, the temperature in the output is displayed as 0.
418
Interfaces