Users Guide

Table Of Contents
Version Description
E-Series original
Command
Usage
Information
Prior to using this command, to place the interface in Layer 2 mode, use the switchport command.
To remove the trunk port designation, first remove the port (using the no member interface
command) from all stackable VLAN-enabled VLANs.
In Example 1, a VLAN-Stack trunk port is configured and then made part of a single-tagged VLAN.
In Example 2, the tag protocol identifier (TPID) is set to 88A8. The Te 3/10 port is configured to act as
a VLAN-Stack access port; the Te 5/1 port acts as a VLAN-Stack trunk port, switching stackable VLAN
traffic for VLAN 10, while also switching untagged traffic for VLAN 30 and tagged traffic for VLAN 40.
(To allow VLAN 30 traffic, you need the native VLAN feature. Use the portmode hybrid command.
For more information, see the portmode hybrid command.
Example 1
DellEMC(conf-if-te-1/42)# switchport
DellEMC(conf-if-te-1/42)# vlan-stack trunk
DellEMC(conf-if-te-1/42)# show config
!
interface TenGigabitEthernet 1/42
no ip address
switchport
vlan-stack trunk
no shutdown
DellEMC(conf-if-te-1/42)# interface vlan 100
DellEMC(conf-if-vl-100)# vlan-stack compatible
DellEMC(conf-if-vl-100-stack)# member tengigabitethernet 1/42
DellEMC(conf-if-vl-100-stack)# show config
!
interface Vlan 100
no ip address
vlan-stack compatible
member TenGigabitEthernet 1/42
shutdown
DellEMC(conf-if-vl-100-stack)# interface vlan 20
DellEMC(conf-if-vl-20)# tagged Tengigabitethernet 1/42
DellEMC(conf-if-vl-20)# show config
!
interface Vlan 20
no ip address
tagged TenGigabitEthernet 1/42
shutdown
DellEMC(conf-if-vl-20)# do show vlan
Codes: * - Default VLAN, G - GVRP VLANs
Q: U - Untagged, T - Tagged
x - Dot1x untagged, X - Dot1x tagged
G - GVRP tagged, M - Vlan-stack
NUM Status Description Q Ports
* 1 Inactive
20 Active T Te 1/42
100 Active M Te 1/42
DellEMC(conf-if-vl-20)#
Example 2
DellEMC(config)# vlan-stack protocol-type 88A8
DellEMC(config)# interface TenGigabitethernet 3/10
DellEMC(conf-if-te-3/10)# no shutdown
DellEMC(conf-if-te-3/10)# switchport
DellEMC(conf-if-te-3/10)# vlan-stack access
DellEMC(conf-if-te-3/10)# exit
DellEMC(config)# interface TenGigabitethernet 5/1
DellEMC(conf-if-te-5/1)# no shutdown
DellEMC(conf-if-te-5/1)# portmode hybrid
DellEMC(conf-if-te-5/1)# switchport
VLAN Stacking 1665