Service Manual

switchport
no shutdown
s60-1#show interfaces port-channel 100 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 100 L2 up 03:33:48 Te 1/8 (Up)
Te 1/30 (Up)
Verify VLT is up. Verify that the VLTi (ICL) link, backup link connectivity (heartbeat status), and VLT peer
link (peer chassis) are all up.
Dell#show vlt br
VLT Domain Brief
------------------
Domain ID : 1
Role : Secondary
Role Priority : 32768
ICL Link Status : Up
HeartBeat Status : Up
VLT Peer Status : Up
Version : 6(3)
Local System MAC address : 00:01:e8:8a:e9:91
Remote System MAC address : 00:01:e8:8a:e9:76
Remote system version : 6(3)
Delay-Restore timer : 90 seconds
Delay-Restore Abort Threshold : 60 seconds
Peer-Routing : Disabled
Peer-Routing-Timeout timer : 0 seconds
Multicast peer-routing timeout : 150 seconds
Dell#
Verify that the VLT LAG is up in VLT peer unit.
Dell-2#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 2 L2L3 up 03:43:24 Te 1/4 (Up)
Dell-4#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 2 L2L3 up 03:33:31 Te 1/18 (Up)
PVST+ Configuration
PVST+ is supported in a VLT domain.
Before you configure VLT on peer switches, configure PVST+ in the network. PVST+ is required for initial
loop prevention during the VLT startup phase. You may also use PVST+ for loop prevention in the
network outside of the VLT port channel.
Run PVST+ on both VLT peer switches. PVST+ instance will be created for every VLAN configured in the
system. PVST+ instances running in the Primary Peer will control the VLT-LAGs on both Primary and
1026
Virtual Link Trunking (VLT)