Administrator Guide

Figure 128. Creating a New Stack
In the above example, stack unit 1 is the master management unit, stack unit 2 is the standby unit. The cables are connected to each unit.
Configure the stack groups on the units in the following order:
Configure the first stack group on unit 1: stack-unit 1 stack-group 13
Configure the stack groups on unit 2: stack-unit 2 stack-group 14 and stack-unit 2 stack-group 15
Configure the stack groups on unit 3: stack-unit 3 stack-group 12 and stack-unit 3 stack-group 13
Configure the stack groups on unit 4: stack-unit 4 stack-group 13 and stack-unit 4 stack-group 14
Configure the final stack-group on unit 1 to complete the stack: stack-unit 1 stack-group 12
When the stack-group configuration is complete, the system prints a syslog for reload.
DellEMC#configure
DellEMC(conf)#stack-unit 4 stack-group 13
DellEMC(conf)#02:39:12: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/52 have been
configured as
stacking ports. Please save and reload for config to take effect
DellEMC(conf)#stack-unit 4 stack-group 14
DellEMC(conf)#02:39:15: %STKUNIT4-M:CP %IFMGR-6-STACK_PORTS_ADDED: Ports Fo 4/53 have been
configured as
stacking ports. Please save and reload for config to take effect
DellEMC(conf)#
DellEMC#02:39:18: %STKUNIT4-M:CP %SYS-5-CONFIG_I: Configured from console
Reload each unit in the stack. After the reload is complete, the four units come up as a stack with unit 1 as the management unit, unit 2 as
the standby unit, and the remaining units as stack-members. All units in the stack can be accessed from the management unit.
NOTE: Before executing show commands, you must wait for 10 to 15 seconds for the download-agent process to start.
To view the stack unit information after the reload, use the show system brief command.
DellEMC#show system brief
Stack MAC : 34:17:eb:f2:94:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
1 Management online S4048-ON S4048-ON 1-0(0-5005) 72
2 Standby online S4048-ON S4048-ON 1-0(0-5005) 72
3 Member online S4048-ON S4048-ON 1-0(0-5005) 72
4 Member online S4048-ON S4048-ON 1-0(0-5005) 72
5 Member not present
6 Member not present
-- Power Supplies --
Stacking