Administrator Guide

FIP Snooping in a Switch Stack
FIP snooping supports switch stacking as follows:
A switch stack conguration is synchronized with the standby stack unit.
Dynamic population of the FCoE database (ENode, Session, and FCF tables) is synchronized with the standby stack unit. The FCoE
database is maintained by snooping FIP keep-alive messages.
In case of a failover, the new master switch starts the required timers for the FCoE database tables. Timers run only on the master
stack unit.
Using FIP Snooping
There are four steps to congure FCoE transit.
1 Enable the FCoE transit feature on a switch.
2 Enable FIP snooping globally on all Virtual Local Area Networks (VLANs) or individual VLANs on a FIP snooping bridge.
3 Congure the FC-Map value applied globally by the switch on all VLANs or an individual VLAN.
4 Congure FCF mode for a FIP snooping bridge-to-FCF link.
For a sample FIP snooping conguration, refer to FIP Snooping Conguration Example.
Statistical information is available for FIP Snooping-related information. For available commands, refer to the FCoE Transit chapter in the
Dell Networking OS Command Line Reference Guide.
FIP Snooping Prerequisites
Before you enable FCoE transit and congure FIP snooping on a switch, ensure that certain conditions are met.
A FIP snooping bridge requires data center bridging exchange protocol (DCBx) and priority-based ow control (PFC) to be enabled on the
switch for lossless Ethernet connections (refer to the Data Center Bridging (DCB) chapter). Dell Networking recommends also enabling
enhanced transmission selection (ETS); however, ETS is recommended but not required.
If you enable DCBx and PFC mode is on (PFC is operationally up) in a port conguration, FIP snooping is operational on the port. If the PFC
parameters in a DCBx exchange with a peer are not synchronized, FIP and FCoE frames are dropped on the port after you enable the FIP
snooping feature.
For VLAN membership, you must:
create the VLANs on the switch which handles FCoE trac (use the interface vlan command).
congure each FIP snooping port to operate in Hybrid mode so that it accepts both tagged and untagged VLAN frames (use the
portmode hybrid command).
congure tagged VLAN membership on each FIP snooping port that sends and receives FCoE trac and has links with an FCF, ENode
server, or another FIP snooping bridge (use the tagged port-type slot/port command).
The default VLAN membership of the port must continue to operate with untagged frames. FIP snooping is not supported on a port that is
congured for non-default untagged VLAN membership.
Important Points to Remember
Enable DCBx on the switch before enabling the FIP Snooping feature.
To enable the feature on the switch, congure FIP Snooping.
To allow FIP frames to pass through the switch on all VLANs, enable FIP snooping globally on a switch.
A switch can support a maximum eight VLANs. Congure at least one FCF/bridge-to-bridge port mode interface for any FIP snooping-
enabled VLAN.
326