Administrator Guide

Example of the redundancy force-failover stack-unit Command
Dell#redundancy force-failover stack-unit
System configuration has been modified. Save? [yes/no]: yes
Proceed with Stack-unit hot failover [confirm yes/no]:yes
Dell#
Specifying an Auto-Failover Limit
When a non-recoverable fatal error is detected, an automatic failover occurs.
However, Dell Networking OS is congured to auto-failover only three times within any 60 minute period and you cannot change that.
Disabling Auto-Reboot
To disable auto-reboot, use the following command.
Prevent a failed stack unit from rebooting after a failover.
CONFIGURATION mode
redundancy disable-auto-reboot
Manually Synchronizing Management and Standby Units
To manually synchronize Management and Standby units at any time, use the following command.
Manually synchronize Management and Standby units.
EXEC Privilege mode
redundancy synchronize full
Pre-Conguring a Stack Unit Slot
You may also pre-congure an empty stack unit slot with a logical stack unit.
To pre-congure an empty stack unit slot, use the following command.
Pre-congure an empty stack unit slot with a logical stack unit.
CONFIGURATION mode
stack-unit unit_id provisionS4048–ON
Example of Viewing a Logical Conguration of a Pre-Congured Stack Unit
After creating the logical stack unit, you can congure the interfaces on the stack unit as if it is present.
Removing a Provisioned Logical Stack Unit
To remove the line card conguration, use the following command.
To remove a logical stack-unit conguration, use the following command:
CONFIGURATION mode
no stack-unit unit_id provision
366