Administrator Guide

The following command shows how to get a MIB object value using the object name.
> snmpget -v 2c -c private -m ./f10-copy-config.mib 10.11.131.140 copyTimeCompleted.110
FTOS-COPY-CONFIG-MIB::copyTimeCompleted.110 = Timeticks: (1179831) 3:16:38.31
The following command shows how to get a MIB object value using OID.
> snmpget -v 2c -c private 10.11.131.140 .1.3.6.1.4.1.6027.3.5.1.1.1.1.13.110
SNMPv2-SMI::enterprises.6027.3.5.1.1.1.1.13.110 = Timeticks: (1179831) 3:16:38.31
MIB Support for Power Monitoring
Dell Networking provides MIB objects to display the information for Power Monitoring. The OIDs specic to Power Monitoring are
appended to the DellITaMIbs. There are three separate DellITaMIbs available to display the current input power, average input power and
average input-power start time. These statistics can also be obtained by using the CLI command:
show environment
. The following table
lists the related MIB objects, OID and description for the same:
Table 93. MIB Objects to Display the Information for Power Monitoring
MIB Object OID Description
envMonSupplyCurrentPower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5 Displays per PSU input power (current
conguration).
envMonSupplyAveragePower 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6 Displays average input power.
envMonSupplyAvgStartTime 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7 Displays average input-power start time.
SNMP Walk Example Output
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.5
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.11 = INTEGER: 48
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.5.12 = INTEGER: 40
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.6
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.11 = INTEGER: 31
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.6.12 = INTEGER: 26
snmpwalk -v 2c -c public 10.16.131.156 1.3.6.1.4.1.674.10895.3000.1.2.110.7.2.1.7
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.11 = STRING: "04/25/2017-18:32"
SNMPv2-SMI::enterprises.674.10895.3000.1.2.110.7.2.1.7.12 = STRING: "04/25/2017-18:32"
MIB Support to Display the Available Memory Size on
Flash
Dell Networking provides more MIB objects to display the available memory size on ash memory. The following table lists the MIB object
that contains the available memory size on ash memory.
Table 94. MIB Objects for Displaying the Available Memory Size on Flash via SNMP
MIB Object OID Description
chStackUnitFlashUsageUtil 1.3.6.1.4.1.6027.3.10.1.2.9.1.6 Contains ash memory usage in percentage.
The chStackUnitUtilTable MIB table contains the chStackUnitFlashUsageUtil MIB object which contains the ash memory usage percent.
The chStackUnitUtilTable is located in f10SSerChassisMib MIB.
Viewing the Available Flash Memory Size
876