Service Manual

Table Of Contents
● Speeds less than 1 Gig cannot be configured when the asymmetric flow control configuration is on.
The following error is returned:
Can’t configure speed <1G when Asymmetric flowcontrol is on, config
ignored
● Dell Networking OS only supports rx on tx on and rx off tx off for speeds less than 1 Gig
(Symmetric).
NOTE: If you use the disable rx flow control command, Dell Networking recommends
rebooting the system.
Example
Dell(conf-if-Te-1/1)# show config
!
interface TenGigabitEthernet 1/1
no ip address
switchport
no negotiation auto
flowcontrol rx off tx on
no shutdown
...
Example (Values)
This Example shows how Dell Networking OS negotiates the flow control values between two Dell
Networking chassis connected back-to-back using 1G copper ports.
Configured
LocRxConf LocTxConf RemoteRxConf RemoteTxConf
off off off off
off on
on off
on on
off on off off
off on
on off
on on
on off off off
off on
on off
on on
on on off off
off on
on off
on on
LocNegRx LocNegTx RemNegRx RemNegTx
off off off off
off off off off
off off off off
off off off off
off off off off
off off off off
off on on off
off off off off
off off off off
on off off on
on on on on
on on on on
off off off off
off off off off
on on on on
on on on on
614