Administrator Guide

Master priority : 10
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 52 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:83:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 1 up UNKNOWN up 10768
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
2 1 up up 10031 up 10031
2 2 up up 10031 up 10031
2 3 up up 10134 up 10031
Speed in RPM
-- Unit 3 --
Unit Type : Member Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 5
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 45 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:99:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
3 1 up UNKNOWN up 10704
3 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
3 1 up up 10031 up 10031
3 2 up up 9929 up 10031
3 3 up up 10031 up 10134
Speed in RPM
Dell#
A change in the stack master occurs when:
You power down the stack master or bring the master switch offline.
A failover of the master switch occurs.
You disconnect the master switch from the stack.
When a stack reloads and all the units come up at the same time; for example, when all units boot up from flash, all units participate in the
election and the master and standby are chosen based on the priority or MAC address.
896
Stacking