Administrator Guide
Version Description
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced.
Usage Information
Use this command to configure the UP and/or DOWN threshold for the scaled metric of a tracked IPv4 or IPv6
route.
Determine the UP/DOWN state of a tracked route by the threshold for the current value of the route metric in
the routing table. To provide a common tracking interface for different clients, route metrics are scaled in the
range 0 to 255, where 0 is connected and 255 is inaccessible. The scaled metric value communicated to a client
always considers a lower value to have priority over a higher value.
The resulting scaled value is compared against the configured threshold values to determine the state of a tracked
route as follows:
• If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP.
• If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in
the routing table, the state of a route is DOWN.
Configure the UP and DOWN thresholds for each tracked route with the threshold metric command. The
default UP threshold is 254; the default DOWN threshold is 255. The notification of a change in the state of a
tracked object is sent when a metric value crosses a configured threshold.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a
scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for
supported protocols with the
track resolution ip route and track resolution ipv6 route
commands.
Related
Commands
• track ip route metric threshold – configure object tracking on the threshold of an IPv4 route metric.
• track resolution ip route – configure the protocol-specific resolution value used to scale an IPv4 route metric.
track interface ip routing
Configure object tracking on the routing status of an IPv4 Layer 3 interface.
Syntax
track object-id interface interface ip routing
To return to the default setting, use the no track object-id command.
Parameters
object-id
Enter the ID number of the tracked object. The range is 1 to 500.
interface
Enter one of the following values:
• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port/subport[/subport] information.
• For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
•
For a Loopback interface, enter the keyword loopback then a number from 0 to
16383.
• For a port channel interface, enter the keywords port-channel then a number.
• For a tunnel interface, enter the keyword tunnel.
Object Tracking 1065