Administrator Guide

Version Description
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
8.3.12.0 Introduced on the S4810.
8.4.1.0 Introduced.
Usage Information
Use this command to configure the UP and/or DOWN threshold for the scaled metric of a tracked IPv4 or IPv6
route.
Determine the UP/DOWN state of a tracked route by the threshold for the current value of the route metric in
the routing table. To provide a common tracking interface for different clients, route metrics are scaled in the
range 0 to 255, where 0 is connected and 255 is inaccessible. The scaled metric value communicated to a client
always considers a lower value to have priority over a higher value.
The resulting scaled value is compared against the configured threshold values to determine the state of a tracked
route as follows:
If the scaled metric for a route entry is less than or equal to the UP threshold, the state of a route is UP.
If the scaled metric for a route is greater than or equal to the DOWN threshold or the route is not entered in
the routing table, the state of a route is DOWN.
Configure the UP and DOWN thresholds for each tracked route with the threshold metric command. The
default UP threshold is 254; the default DOWN threshold is 255. The notification of a change in the state of a
tracked object is sent when a metric value crosses a configured threshold.
The tracking process uses a protocol-specific resolution value to convert the actual metric in the routing table to a
scaled metric in the range 0 to 255. You can configure the resolution value used to scale route metrics for
supported protocols with the
track resolution ip route and track resolution ipv6 route
commands.
Related
Commands
track ip route metric threshold – configure object tracking on the threshold of an IPv4 route metric.
track resolution ip route – configure the protocol-specific resolution value used to scale an IPv4 route metric.
track interface ip routing
Configure object tracking on the routing status of an IPv4 Layer 3 interface.
Syntax
track object-id interface interface ip routing
To return to the default setting, use the no track object-id command.
Parameters
object-id
Enter the ID number of the tracked object. The range is 1 to 500.
interface
Enter one of the following values:
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port/subport[/subport] information.
For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/
port information.
For a Loopback interface, enter the keyword loopback then a number from 0 to
16383.
For a port channel interface, enter the keywords port-channel then a number.
For a tunnel interface, enter the keyword tunnel.
Object Tracking 1065