Administrator Guide

authenticated with the new key. This process ensures that the neighbors learn the new key and communication is
not disrupted by keeping the old key enabled.
After the reply is received and the new key is authenticated, delete the old key. Dell EMC recommends keeping
only one key per interface.
NOTE: The MD5 secret is stored as plain text in the configuration file with service password
encryption. Write down or otherwise record the key. You cannot learn the key once it is
configured. Use caution when changing the key.
ip ospf mtu-ignore
Disable OSPF MTU mismatch detection upon receipt of database description (DBD) packets.
S4048–ON
Syntax
ip ospf mtu-ignore
To return to the default, use the no ip ospf mtu-ignore command.
Defaults Enabled.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
pre- 6.1.1.1 Introduced on the E-Series.
ip ospf network
Set the network type for the interface.
S4048–ON
Syntax
ip ospf network {broadcast | point-to-point}
To return to the default, use the no ip ospf network command.
Open Shortest Path First (OSPFv2 and OSPFv3) 1103