vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the stackable VLAN network.
Syntax
vlan-stack trunk
To remove a trunk port designation from the selected interface, use the no vlan-stack trunk command.
Defaults Not configured.
Command Modes INTERFACE
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100–ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series. C-Series and S-Series accept both bytes of the 2-byte S-Tag
TPID.
7.8.1.0 Functionality augmented for C-Series and S-Series to enable multi-purpose use of the
port.
7.7.1.0 Functionality augmented for E-Series to enable multi-purpose use of the port.
7.6.1.0 Introduced on the C-Series and S-Series.
E-Series original
Command
Usage Information
Prior to using this command, to place the interface in Layer 2 mode, use the switchport command.
To remove the trunk port designation, first remove the port (using the no member interface command)
from all stackable VLAN-enabled VLANs.
In Example 1, a VLAN-Stack trunk port is configured and then made part of a single-tagged VLAN.
In Example 2, the tag protocol identifier (TPID) is set to 88A8. The Te 3/10 port is configured to act as a VLAN-
Stack access port; the
Te 5/1 port acts as a VLAN-Stack trunk port, switching stackable VLAN traffic for VLAN
10, while also switching untagged traffic for VLAN 30 and tagged traffic for VLAN 40. (To allow VLAN 30 traffic,
you need the native VLAN feature. Use the portmode hybrid command. For more information, see the
portmode hybrid command.
Example 1
DellEMC(conf-if-te-1/42)# switchport
DellEMC(conf-if-te-1/42)# vlan-stack trunk
DellEMC(conf-if-te-1/42)# show config
!
interface TenGigabitEthernet 1/42
VLAN Stacking 1651