Concept Guide
FCoE Transit Conguration Example
The following illustration shows a switch used as a FIP snooping bridge for FCoE trac between an ENode (server blade) and an FCF (ToR
switch). The ToR switch operates as an FCF and FCoE gateway.
Figure 40. Conguration Example: FIP Snooping on a Switch
In this example, DCBx and PFC are enabled on the FIP snooping bridge and on the FCF ToR switch. On the FIP snooping bridge, DCBx is
congured as follows:
• A server-facing port is congured for DCBx in an auto-downstream role.
• An FCF-facing port is congured for DCBx in an auto-upstream or conguration-source role.
The DCBx conguration on the FCF-facing port is detected by the server-facing port and the DCB PFC conguration on both ports is
synchronized. For more information about how to congure DCBx and PFC on a port, refer to the Data Center Bridging (DCB) chapter.
The following example shows how to congure FIP snooping on FCoE VLAN 10, on an FCF-facing port (1/5), on an ENode server-facing
port (1/1), and to congure the FIP snooping ports as tagged members of the FCoE VLAN enabled for FIP snooping.
Example of Enabling the FIP Snooping Feature on the Switch (FIP Snooping Bridge)
DellEMC(conf)# feature fip-snooping
Example of Enabling FIP Snooping on the FCoE VLAN
DellEMC(conf)# interface vlan 10
DellEMC(conf-if-vl-10)# fip-snooping enable
Example of Enabling an FC-MAP Value on a VLAN
DellEMC(conf-if-vl-10)# fip-snooping fc-map 0xOEFC01
NOTE
: Conguring an FC-MAP value is only required if you do not use the default FC-MAP value (0x0EFC00).
358 FIP Snooping