Connectivity Guide

Table Of Contents
0 major EQM_MORE_PSU_FAULT Sep 7 18:36:11 Node.1-Unit.1
1 major EQM_FAN_AIRFLOW_MISMATCH Sep 7 18:36:11 Node.1-Unit.1
Supported Releases 10.2.0E or later
show alarms details
Displays details about active alarms.
Syntax
show alarms details
Parameters None
Default Not congured
Command Mode EXEC
Usage Information None
Example
OS10# show alarms details
Active-alarm details - 0
-------------------------------------------
Index: 0
Sequence Number: 1
Severity: critical
Type: 1081367
Source: Node.1-Unit.1
Name: EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time: Sep 20 0:1:5
Clear-time:
New: true
State: raised
-------------------------------------------
Active-alarm details - 1
-------------------------------------------
Index: 1
Sequence Number: 5
Severity: warning
Type: 1081364
Source: Node.1-Unit.1
Name: EQM_THERMAL_WARN_CROSSED
Description:
Raise-time: Sep 20 0:16:52
Clear-time:
New: true
State: raised
Supported Releases
10.2.0E or later
show alarms history
Displays the history of cleared alarms.
Syntax
show alarms history [summary]
Parameters summary — Enter to view a summary of the alarm history.
Default Not congured
Command Mode EXEC
970 Troubleshoot OS10