Connectivity Guide

Table Of Contents
Parameters severity — Set the alarm severity:
critical — Critical alarm severity.
major — Major alarm severity.
minor — Minor alarm severity.
warning — Warning alarm severity.
Default Not congured
Command Mode EXEC
Usage Information None
Example (Warning)
OS10# show alarms severity warning
Active-alarm details - 1
-------------------------------------------
Index: 1
Sequence Number: 5
Severity: warning
Type: 1081364
Source: Node.1-Unit.1
Name: EQM_THERMAL_WARN_CROSSED
Description:
Raise-time: Sep 20 0:16:52
Clear-time:
New: true
State: raised
Example (Critical)
OS10# show alarms severity critical
Active-alarm details - 0
-------------------------------------------
Index: 0
Sequence Number: 1
Severity: critical
Type: 1081367
Source: Node.1-Unit.1
Name: EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time: Sep 20 0:1:5
Clear-time:
New: true
State: raised
Supported Releases 10.2.0E or later
show alarms summary
Displays the summary of alarm information.
Syntax
show alarms summary
Parameters None
Default Not congured
Command Mode EXEC
Usage Information None
Example
OS10# show alarms summary