Concept Guide

Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 52 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:83:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
2 1 up UNKNOWN up 10768
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
2 1 up up 10031 up 10031
2 2 up up 10031 up 10031
2 3 up up 10134 up 10031
Speed in RPM
-- Unit 3 --
Unit Type : Member Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 5
Hardware Rev : 2.0
Num Ports : 72
Up Time : 33 min, 45 sec
Dell Networking OS Version : 1-0(0-5005)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:99:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
3 1 up UNKNOWN up 10704
3 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
3 1 up up 10031 up 10031
3 2 up up 9929 up 10031
3 3 up up 10031 up 10134
Speed in RPM
DellEMC#
A change in the stack master occurs when:
You power down the stack master or bring the master switch oine.
A failover of the master switch occurs.
You disconnect the master switch from the stack.
When a stack reloads and all the units come up at the same time; for example, when all units boot up from ash, all units participate in the
election and the master and standby are chosen based on the priority or MAC address.
Stacking
981