Users Guide

Dell(conf)#monitor session 0
Dell(conf-mon-sess-0)#source po 10 dest ten 1/2 dir rx
Dell(conf-mon-sess-0)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
0 Te 1/1 Te 1/2 rx Port N/A N/A
0 Po 10 Te 1/2 rx Port N/A N/A
Dell(conf)#monitor session 1
Dell(conf-mon-sess-1)#source vl 40 dest ten 1/3 dir rx
Dell(conf-mon-sess-1)#flow-based enable
Dell(conf-mon-sess-1)#exit
Dell(conf)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
0 Te 1/1 Te 1/2 rx Port N/A N/A
0 Po 10 Te 1/2 rx Port N/A N/A
1 Vl 40 Te 1/3 rx Flow N/A N/A
NOTE: Source as VLAN is achieved via Flow based mirroring. Please refer section Enabling Flow-Based Monitoring.
In the following example, the host and server are exchanging traffic which passes through the uplink interface 1/1. Port 1/1 is the
monitored port and port 1/42 is the destination port, which is configured to only monitor traffic received on tengigabitethernet 1/1 (host-
originated traffic).
Figure 101. Port Monitoring Example
Configuring Monitor Multicast Queue
To configure monitor QoS multicast queue ID, use the following commands.
1. Configure monitor QoS multicast queue ID.
CONFIGURATION mode
monitor multicast-queue queue-id
Dell(conf)#monitor multicast-queue 7
Port Monitoring
585