API Guide
Node Id              : 1
MAC                  : 14:18:77:15:c3:e8
Number of MACs       : 256
Up Time              : 1 day 00:48:58
-- Unit 1 --
Status                     : up
System Identifier          : 1
Down Reason                : unknown
Digital Optical Monitoring : disable
System Location LED        : off
Required Type              : S4148F
Current Type               : S4148F
Hardware Revision          : X01
Software Version           : 10.5.0.0
Physical Ports             : 48x10GbE, 2x40GbE, 4x100GbE
BIOS                          : 3.33.0.0-3
System CPLD                   : 0.4
Master CPLD                   : 0.10
Slave CPLD                    : 0.7
-- Power Supplies --
PSU-ID  Status      Type    AirFlow   Fan  Speed(rpm)  Status
----------------------------------------------------------------
1       up          AC      NORMAL    1    13312       up
2       fail
-- Fan Status --
FanTray  Status      AirFlow   Fan  Speed(rpm)  Status
----------------------------------------------------------------
1        up          NORMAL    1    13195       up
2        up          NORMAL    1    13151       up
3        up          NORMAL    1    13239       up
4        up          NORMAL    1    13239       up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
● chassis/slot/port[:subport] — Enter the ethernet interface number.
● on | off — Set the interface LED to be on or off.
Default Not configured
Command Mode EXEC
Usage
Information
Use this command to change the location LED for the specified interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported
Releases
10.3.0E or later
Troubleshoot Dell EMC SmartFabric OS10 1399