Connectivity Guide
State Machine Type is Asymmetric
Conf TLV Tx Status is enabled
Reco TLV Tx Status is enabled
5 Input Conf TLV Pkts, 2 Output Conf TLV Pkts, 0 Error Conf TLV Pkts
5 Input Reco TLV Pkts, 2 Output Reco TLV Pkts, 0 Error Reco TLV Pkts
Example (PFC 
detail)
OS10# show lldp dcbx interface ethernet 1/1/15 pfc detail
Interface ethernet1/1/15
 Admin mode is on
 Admin is enabled, Priority list is 4,5,6,7 
 Remote is enabled, Priority list is 4,5,6,7 
 Remote Willing Status is disabled 
 Local is enabled, Priority list is 4,5,6,7 
 Oper status is init 
 PFC DCBX Oper status is Up 
 State Machine Type is Symmetric 
 PFC TLV Tx Status is enabled
 Application Priority TLV Parameters :
 --------------------------------------
 ISCSI TLV Tx Status is enabled
 Local ISCSI PriorityMap is 0x10 
 Remote ISCSI PriorityMap is 0x10 
 5 Input TLV pkts, 2 Output TLV pkts, 0 Error pkts
 5 Input Appln Priority TLV pkts, 2 Output Appln Priority TLV pkts, 0 Error 
Appln Priority TLV Pkts
Supported Releases 10.3.0E or later
Internet small computer system interface
iSCSI is a TCP/IP-based protocol that establishes and manages connections between servers and storage devices in a data center 
network. After you enable iSCSI, iSCSI optimization automatically detects Dell EMC EqualLogic storage arrays directly attached to switch 
ports. To support storage arrays where auto-detection is not supported, manually congure iSCSI optimization using the iscsi 
profile-storage 
name command.
iSCSI optimization enables a switch to auto-detect Dell EMC’s iSCSI storage arrays and auto-congure switch ports to improve storage 
trac throughput. The switch monitors iSCSI sessions and applies QoS policies on iSCSI trac. iSCSI optimization operates with or 
without DCBX over an Ethernet network.
• iSCSI uses the current ow-control conguration by default. If you do not congure ow-control, iSCSI auto-congures ow control 
settings so that receive-only is enabled and transmit-only is disabled.
• The switch monitors and tracks active iSCSI sessions, including port information and iSCSI session information.
• A user-congured iSCSI CoS prole applies to all iSCSI trac. Use classier rules to direct the iSCSI data trac to queues with 
preferential QoS treatment over other data passing through the switch. Preferential treatment helps to avoid session interruptions 
during times of congestion that would otherwise cause dropped iSCSI packets.
1104
Converged data center services