Users Guide

Default None
Command Mode EXEC
Usage
Information
The output of the show alarms details command indicates if an alarm is acknowledged or not. If an
alarm is not acknowledged, the Acknowledged field is set to false and the Ack-time value is empty.
If an alarm is acknowledged, the Acknowledged field is set to true and the system displays the time
the alarm was acknowledged.
Example
Alarm is not acknowledged:
OS10# show alarms details
Active-alarm details - 732
-------------------------------------------
Sequence Number: 732
Severity: critical
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Mon Jul 29 06:12:30 2019
Ack-time:
New: true
Acknowledged: false
-------------------------------------------
Alarm is acknowledged:
OS10# show alarms details
Active-alarm details - 732
-------------------------------------------
Sequence Number: 732
Severity: critical
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Mon Jul 29 06:12:30 2019
Ack-time: Mon Jul 29 06:16:35 2019
New: true
Acknowledged: true
-------------------------------------------
Supported
Releases
10.2.0E or later
show alarms sequence
Displays information corresponding to the active alarm based on the sequence number that you specify.
Syntax
show alarms sequence sequence-number
Parameters
sequence-number Enter the sequence number corresponding to the active alarm.
Default None
Command Mode EXEC
Usage
Information
Use the show alarms command to view all active alarms. Use an active alarm sequence number to view
detailed information about that alarm.
Example
NOS# show alarms sequence 3
Active-alarm details - 1
------------------------------------------
Sequence Number: 3
Severity: major
Type: 1081375
Source: /psu/2
1812 Troubleshoot Dell EMC SmartFabric OS10