To verify the fabric name server registration on switch-2, run the show fc ns fabric command.
OS10#show fc ns fabric
Total number of devices = 2
Switch Name 20:00:44:18:37:10:73:0a
Domain Id 119
Switch Port FC1/1/1
FC-Id 77:00:02
Port Name 20:02:00:11:0d:a5:56:01
Node Name 20:02:00:11:0d:a5:56:00
Class of Service 8
Symbolic Port Name XXX
Symbolic Node Name XXX
Port Type N_Port
Registered with NameServer Yes
Registered for SCN No
FC4-Types:FC4-Features fcp(0x08):0x1
Switch Name 10:00:14:18:77:20:73:cf
Domain Id 101
Switch Port FC1/1/1
FC-Id 65:00:01
Port Name 20:01:f4:e9:d4:f9:fc:44
Node Name 20:00:f4:e9:d4:f9:fc:43
Class of Service 8
Symbolic Port Name XXX
Symbolic Node Name XXX
Port Type N_Port
FC4-Types:FC4-Features fcp(0x08):0x2
To display the zone set, run the show fc zoneset command.
OS10#show fc zoneset | no-more
ZoneSetName ZoneName ZoneMember
==============================================================
zoneset1 zoneA 20:01:f4:e9:d4:f9:fc:44
20:02:00:11:0d:a5:56:01
vFabric id: 1
Active Zoneset: zoneset1
ZoneName ZoneMember
==============================================================
zoneA 20:01:f4:e9:d4:f9:fc:44
20:02:00:11:0d:a5:56:01
To verify the vFabric in switch-1, run the show vfabric command.
OS10# show vfabric
Fabric Name SAN_FABRIC
Fabric Type Multi-Switch
Fabric Id 1
VlanId 1001
FC-MAP 0xEFC00
Config-State ACTIVE
Oper-State UP
==========================================
Switch Config Parameters
==========================================
Domain ID 101
Switch Priority 128
E-D-TOV(ms) 1000
R-A-TOV(ms) 5000
==========================================
Switch Fabric Parameters
==========================================
Run Time Domain ID 101
Run Time Switch Priority 128
==========================================
Switch Zoning Parameters
==========================================
Default Zone Mode: Deny
Active ZoneSet: zoneset1
444
Fibre Channel