Users Guide

21:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
22:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
23:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
OS10#re-balance npg sessions vfabric 100
Fabric Id 100 State before Re-balancing
Uplink FLOGI FDISC Load Speed Excess
Intf (Gbps) Load
-----------------------------------------------------------------
Fc 1/1/1 1 9 10 8 7
Fc 1/1/2 3 3 6 16 0
-----------------------------------------------------------------
4 12 16 24 7
-----------------------------------------------------------------
Session Displacements:
Total No. of Node(s) : 4
No. of Node(s) displaced : 4
-------------------------------------------------------------------------------------
Node WWPN From Uplink Intf To Uplink Intf No.of sessions
-------------------------------------------------------------------------------------
20:01:d4:ae:52:1a:ee:54 Fc 1/1/1 Fc 1/1/2 10
21:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
22:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
23:01:d4:ae:52:1a:ee:54 Fc 1/1/2 Fc 1/1/1 2
Fabric Id 100 Expected State after Re-balancing
Uplink FLOGI FDISC Load Speed Excess
Intf (Gbps) Load
---------------------------------------------------------------------
Fc 1/1/1 3 3 6 8 1
Fc 1/1/2 1 9 10 16 0
---------------------------------------------------------------------
4 12 16 24 1
---------------------------------------------------------------------
Supported
Releases
10.4.0E(R1) or later
show npg uplink-interface
Display information in a FC upstream interface.
Syntax
show npg uplink-interfaces [vfabric vfabric-id [fcf-info] | [fcf-info]]
Parameters
fcf-info - FCF Availability Status, fabric name of the FC upstream switch connected, error reason,
FCF advertisement delay timeout left and duplicate FC id assignment counter.
Default Not configured
Command Mode EXEC
Usage
Information
Displays the details of FC upstream interfaces in all the available or specified vFabrics along with the FC Id
and BB Credit.
This command is supported in NPG mode.
The fields and the corresponding descriptions are described as follows:
Uplink IntfThe name of the FC uplink interface.
FCF Availability StatusStatus of the logical FCF of that fabric, whether it is available to establish
session or not. This field takes values as Yes or No.
FAD timeout leftNumber of seconds left for the FCF Advertisement Delay timer to expire.
Upstream fabric nameFabric name of the upstream FC switch/Multi-switch to which this interface
is connected.
Error reasonReason for error in the FC uplink interface. Following are few possible error reasons:
Fibre Channel 503