A virtual extensible LAN (VXLAN) extends Layer 2 (L2) server connectivity over an underlying Layer 3 (L3) transport network in a
virtualized data center. A virtualized data center consists of virtual machines (VMs) in a multi-tenant environment. OS10 supports VXLAN
as described in RFC 7348.
VXLAN provides a L2 overlay mechanism on an existing L3 network by encapsulating the L2 frames in L3 packets. The VXLAN-shared
forwarding domain allows hosts such as virtual and physical machines, in tenant L2 segments to communicate over the shared IP network.
Each tenant L2 segment is identified by a 24-bit ID called a VXLAN network identifier (VNI).
Deployed as a VXLAN gateway, an OS10 switch performs encapsulation/de-encapsulation of L2 frames in L3 packets while tunneling
server traffic. In this role, an OS10 switch operates as a VXLAN tunnel endpoint (VTEP). Using VXLAN tunnels, server VLAN segments
communicate through the extended L2 forwarding domain.
Figure 1. VXLAN topology
NOTE:
The platforms that support only L2 VXLAN gateway include: S4048-ON, Z9100-ON, and Z9264F-ON
The platforms that support both L2 VXLAN and L3 VXLAN routing (Routing In and Out of Tunnels (RIOT)) include:
Asymmetric IRB: S4048T-ON, S4248-ON series, S4100-ON series, S5200-ON series, and S6010-ON
Symmetric IRB: S4048T-ON, S4100-ON series, S5200-ON series, and S6010-ON
After VXLAN decapsulation, routing between virtual networks and tenant VLANs is supported only on the following
platforms:
S4200-ON series
S5200-ON series
On other platforms, routing after decapsulation is performed only between virtual networks. You can connect an egress
virtual network to a VLAN in an external router, which connects to an external network.
This feature is not supported on the following platforms:
S3048F-ON