Reference Guide

1 3ffe:501:ffff:100:201:e8ff:fe00:4c8b
000.000 ms 000.000 ms 000.000 ms
View diagnostics
View system diagnostic information using show commands. The show hash-algorithm command is used to view the current hash
algorithms conīš€gured for LAG and ECMP.
View environment
OS10# show environment
Unit State Temperature
-------------------------------------
1 up 43
Thermal sensors
Unit Sensor-Id Sensor-name Temperature
------------------------------------------------------------------------------
1 1 CPU On-Board temp sensor 32
1 2 Switch board temp sensor 28
1 3 System Inlet Ambient-1 temp sensor 27
1 4 System Inlet Ambient-2 temp sensor 25
1 5 System Inlet Ambient-3 temp sensor 26
1 6 Switch board 2 temp sensor 31
1 7 Switch board 3 temp sensor 41
1 8 NPU temp sensor 43
View hash algorithm
OS10# show hash-algorithm
LagAlgo - CRC EcmpAlgo - CRC
View inventory
OS10# show inventory
Product : S4048ON
Description : S4048-ON 48x10GbE, 6x40GbE QSFP+ Interface Module
Software version : 10.3.9999E(X)
Unit Type Part Number Rev Piece Part ID Svc Tag Exprs Svc Code
-------------------------------------------------------------------------------------------
* 1 S4048ON ----
1 S4048ON-PWR-2-AC-R 0T9FNW X01 TW-0T9FNW-28298-49Q-0034 AEIOU## 226 457 410 55
1 S4048ON-FANTRAY-1-R 0MGDH8 X01 TW-0MGDH8-28298-49Q-0451 AEIOU## 226 457 410 55
1 S4048ON-FANTRAY-2-R 0MGDH8 X01 TW-0MGDH8-28298-49Q-0450 AEIOU## 226 457 410 55
1 S4048ON-FANTRAY-3 P1FAN1 A01 CN-123456-FAN10-058-901
View system information
OS10#show system
Node Id : 1
MAC : 34:17:18:19:20:21
Number of MACs : 0
Up Time : 1 week 4 days 08:08:17
-- Unit 1 --
Status : up
System Identifier : 1
Down Reason :
System Location LED : off
Required Type : S4048
Current Type : S4048
Hardware Revision :
Troubleshoot OS10
675