Users Guide

Table Of Contents
Supported
Releases
10.2.0E or later
show hardware deep-buffer-mode
Displays the status of Deep buffer mode in the current and next boot of the switch.
Syntax
show hardware deep-buffer-mode
Parameters None
Defaults Not configured
Command Modes EXEC
Usage
Information
Applicable only for the S4200-ON series switches.
Example
Example: default setting
OS10# show hardware deep-buffer-mode
Deep Buffer Mode Configuration Status
-------------------------------------------
Current-boot Settings : Disabled
Next-boot Settings : Disabled
Example: saved to startup configuration
OS10# show hardware deep-buffer-mode
Deep Buffer Mode Configuration Status
-------------------------------------------
Current-boot Settings : Disabled
Next-boot Settings : Enabled
Example: switch reloaded
OS10# show hardware deep-buffer-mode
Deep Buffer Mode Configuration Status
-------------------------------------------
Current-boot Settings : Enabled
Next-boot Settings : Enabled
Supported
Releases
10.4.3.0 or later
show interface priority-flow-control
Displays the priority flow-control, operational status, CoS bitmap, and statistics per port.
Syntax
show interface ethernet node/slot/port[:subport] priority-flow-control
[details]
Parameters details (Optional) Displays all priority flow control information for an interface.
Default Not configured
Command Mode EXEC
Usage
Information
None
Example
(Details)
OS10# show interface ethernet 1/1/14 priority-flow-control details
Quality of service 1243