Users Guide

Table Of Contents
1/1/4 FIXED INTERNAL true
1/1/5 FIXED INTERNAL true
1/1/6 FIXED INTERNAL true
1/1/7 FIXED INTERNAL true
1/1/8 FIXED INTERNAL true
...
View internal Ethernet port status
OS10# show interface status
---------------------------------------------------------------------------
Port Description Status Speed Duplex Mode Vlan Tagged-Vlans
---------------------------------------------------------------------------
Eth 1/1/1 down 0 auto A 1 -
Eth 1/1/2 down 0 auto A 1 -
Eth 1/1/3 down 0 auto A 1 -
Eth 1/1/4 down 0 auto A 1 -
Eth 1/1/5 down 0 auto A 1 -
Eth 1/1/6 down 0 auto A 1 -
Eth 1/1/7 down 0 auto A 1 -
Eth 1/1/8 down 0 auto A 1 -
Eth 1/1/9 down 0 auto A 1 -
Eth 1/1/10 down 0 auto A 1 -
Eth 1/1/11 up 25G A 1 -
Eth 1/1/12 down 0 auto A 1 -
Eth 1/1/13 down 0 auto A 1 -
Eth 1/1/14 down 0 auto A 1 -
Eth 1/1/15 down 0 auto A 1 -
Eth 1/1/16 down 0 auto A 1 -
...
Replace MX Ethernet I/O modules
OS10 enables you to replace an Ethernet I/O module (IOM) that is part of a SmartFabric or Full-Switch VLT, when an error
occurs. The replacement mechanism is available for the following IOMs:
MX9116n Fabric Switching Engine (FSE)
MX5108n Ethernet Switch
For information about the MX modules and fabrics, see the Dell EMC PowerEdge MX7000 documentation. For more information
about the operating modes and chassis, see Dell EMC OpenManage Enterprise - Modular documentation. The documents are
available at the Dell EMC Networking website at www.dell.com/support.
Deployment instructions
Dell EMC recommends:
The replacement IOM must be a new device in the chassis deployment.
NOTE: New device means an IOM that is not deployed previously within the OME-Modular multi-chassis group.
If the faulty IOM is in SmartFabric mode, the other IOM in the SmartFabric must be up and running.
The new IOM must be the same model as the faulty IOM. For example: If the faulty IOM model is MX9116n FSE, you must
use a new MX9116n FSE as a replacement IOM.
Ensure that the new IOM has the same OS10 version as the faulty IOM. You can check the OS10 version by logging into the
OME-Modular Graphical User Interface (GUI).
NOTE:
OS10 is factory-installed in the MX9116n FSE or MX5108n Ethernet Switch. If the faulty IOM has an upgraded
version of OS10, you must upgrade the new IOM to the same version. To upgrade an OS10 image, see Download OS10
image for upgrade.
Replace an IOM in Full-Switch VLT
To replace an IOM in Full-Switch mode and part of a VLT domain:
1. Physically remove the faulty IOM and insert the new IOM, see Remove and replace the IOM.
PowerEdge MX Ethernet I/O modules
319