show alarms severity
Displays all active alarms corresponding to a specific severity level.
Syntax
show alarms severity severity
Parameters severity Set the alarm severity:
critical Critical alarm severity.
major Major alarm severity.
minor Minor alarm severity.
warning Warning alarm severity.
Default Not configured
Command Mode EXEC
Usage
Information
None
Example
(Warning)
OS10# show alarms severity warning
Active-alarm details - 1
-------------------------------------------
Sequence Number: 5
Severity: warning
Type: 1081364
Source: Node.1-Unit.1
Name: EQM_THERMAL_WARN_CROSSED
Description:
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example
(Critical)
OS10# show alarms severity critical
Active-alarm details - 0
-------------------------------------------
Sequence Number: 1
Severity: critical
Type: 1081367
Source: Node.1-Unit.1
Name: EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example (Minor)
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number: 4
Severity: minor
Type: 1081375
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------