If the command is run on a member, the system displays only the details of the master IOM. The system displays information
such as service tag and IPv6 address of the master. If the command is run in a master, the system displays the details of
all the IOMs in the chassis deployment. Log in to the master IOM using the displayed IPv6 address before using the module
replacement command.
Also you can view the IPv4 address of the master IOM using the show smartfabric cluster command.
To identify the master IOM:
View the details of the master IOM using the show smartfabric cluster member command in the EXEC mode.
MX9116N-A1# show smartfabric cluster member
If you use the show smartfabric cluster member command on the master IOM, the system displays the following
output:
MX9116N-A1# show smartfabric cluster member
Service-tag IP Address Status Role Type Chassis- Chassis
Service-Tag -Slot
----------------------------------------------------------------------------------------
HRA0024 fde1:53ba:e9a0:de14:2204:fff:fe13:143 ONLINE MASTER MX9116n ARH0006 B2
If you use the show smartfabric cluster member command on the member IOM, the system displays the following
output:
MX9116N-B2# show smartfabric cluster member
Service IP Address Status Role Type Chassis- Chassis
-tag Service-Tag -Slot
-----------------------------------------------------------------------------------------
-
HRA0015 fde1:53ba:e9a0:de14:2204:fff:fe0c:d637 ONLINE BACKUP MX9116n ARH0004
B1
HRA0039 fde1:53ba:e9a0:de14:2204:fff:fe20:5249 ONLINE BACKUP MX9116n ARH0010
B1
HRA0016 fde1:53ba:e9a0:de14:2204:fff:fe0c:e637 ONLINE BACKUP MX9116n ARH0004
B2
HRA0035 fde1:53ba:e9a0:de14:2204:fff:fe21:7fc9 ONLINE BACKUP MX9116n ARH0009
B1
HRA0008 fde1:53ba:e9a0:de14:2204:fff:fe20:7f49 ONLINE BACKUP MX9116n ARH0002
B2
HRA0023 fde1:53ba:e9a0:de14:2204:fff:fe0c:f1b7 ONLINE BACKUP MX9116n ARH0006
B1
HRA0031 fde1:53ba:e9a0:de14:2204:fff:fe16:d553 ONLINE BACKUP MX9116n ARH0008
B1
HRA0036 fde1:53ba:e9a0:de14:2204:fff:fe20:56c9 ONLINE BACKUP MX9116n ARH0009
B2
HRA0019 fde1:53ba:e9a0:de14:2204:fff:fe21:1c9 ONLINE BACKUP MX9116n ARH0005
B1
HRA0017 fde1:53ba:e9a0:de14:2204:fff:fe21:9f49 ONLINE BACKUP MX9116n ARH0005
A1
HRA0032 fde1:53ba:e9a0:de14:2204:fff:fe17:3bd3 ONLINE BACKUP MX9116n ARH0008
B2
HRA0024 fde1:53ba:e9a0:de14:2204:fff:fe13:143 ONLINE MASTER MX9116n ARH0006 B2
...
Log in to the master IOM from the member
To use the module replacement command, access the master IOM from the member.
Use the IPv6 address of the master IOM to log in to the master IOM. After logging in to the master IOM, use the module
replacement command to initiate the replacement workflow.
1. Log in to the Linux shell from EXEC mode in the connected IOM.
OS10# system bash
admin@MX9116N-A2:~$