Users Guide

Table Of Contents
14:18:77:20:80:ce Eth 1/1/42 1002 0e:fc:00 8000
1 F
FSB4# show fcoe system
Mode : FSB
CVL Status : Enabled
FCOE VLAN List (Operational) : 1001,1002
FCFs : 1
Enodes : 1
Sessions : 1
FCF1
FCF1# show fcoe sessions
Enode MAC Enode Interface FCF MAC FCF interface VLAN FCoE
MAC FC-ID PORT WWPN PORT WWNN
-----------------------------------------------------------------------------------------
-------------------------------------------------------
f4:e9:d4:f9:fc:42 Eth 1/1/45 14:18:77:20:86:ce ~ 1001 0e:fc:00:02:02:00
02:02:00 23:05:22:11:0d:64:67:11 22:04:22:13:0d:64:67:00
FCF1# show fc ns switch brief
Total number of devices = 2
Intf# Domain FC-ID Enode-WWPN Enode-WWNN
fibrechannel1/1/3 2 02:00:00 50:00:d3:10:00:ec:f9:00
51:00:d3:10:00:ec:f9:01
ethernet1/1/45 2 02:02:00 23:05:22:11:0d:64:67:11
22:04:22:13:0d:64:67:00
FCF2
FCF2# show fcoe sessions
Enode MAC Enode Interface FCF MAC FCF interface VLAN FCoE
MAC FC-ID PORT WWPN PORT WWNN
-----------------------------------------------------------------------------------------
--------------------------------------------------------
00:0e:1e:f1:f1:84 Eth 1/1/42 14:18:77:20:80:ce ~ 1002 0e:fc:00:02:01:00
02:00:01 20:01:00:0e:1e:f1:f1:84 20:00:00:0e:1e:f1:f1:84
FCF2# show fc ns switch brief
Total number of devices = 2
Intf# Domain FC-ID Enode-WWPN Enode-WWNN
fibrechannel1/1/4 3 02:01:00 53:00:a3:10:00:ec:f9:01
52:00:a3:10:00:ec:f9:00
ethernet1/1/42 3 02:00:01 20:01:00:0e:1e:f1:f1:84
20:00:00:0e:1e:f1:f1:84
Configuration guidelines
When configuring different modes; for example, F_Port, NPG, or FSB, consider the following:
F_Port, NPG, and FSB modes are mutually exclusive. You can enable only one at a time.
You can enable the mode-specific commands only after enabling the specific feature.
Before you disable the F_Port and NPG features, delete the mode-specific configurations. When you disable FSB, the
system automatically removes the configurations.
If you connect a storage device (target) to the IOM Fibrechannel port and if the port is operationally UP, then the storage
device will induce a port flap until you configure the FC DirectAttach uplink (vfabric) configuration on this port. This is
because, the storage device tries to login to the IOM switch and flaps the port in case it does not receive the response. This
is because the IOM side needs to be configured yet. Once you complete the configuration on the IOM side, then flaps are
stopped and storage device logs in to the IOM switch.
476