Reference Guide

Software Version : 10.3.9999E(X)
Physical Ports : 48x10GbE, 6x40GbE
BIOS : 3.21.0.4
System CPLD : 15
Master CPLD : 12
Slave CPLD : 5
-- Power Supplies --
PSU-ID Status Type AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 fail
2 up AC REVERSE 1 14720 up
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
----------------------------------------------------------------
1 up REVERSE 1 13063 up
2 13063 up
2 up REVERSE 1 13020 up
2 12977 up
3 up NORMAL 1 13085 up
2 13063 up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
chassis/slot/port[:subport] — Enter the ethernet interface number.
on | off — Set the interface LED to be on or o.
Default Not congured
Command Mode EXEC
Usage Information Use the location-led interface command to change the location LED for the specied interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported Releases 10.3.0E or later
location-led system
Changes the location LED of the system.
Syntax
location-led system {node-id | node-id/unit-id} {on | off}
Parameters
node-id | node-id/unit-id — Enter the system ID.
on | off — Set the system LED to be on or o.
Troubleshoot OS10 669