API Guide

a. Collect the following information required to execute the
updates.
i. Identify and note the Switch SERVICE-TAG and its
ROLE in the smart fabric cluster by executing the
"show smartfabric cluster" command in the Switch
CLI. This command is executed on all the switches in
single or multi chassis group.
Sample output from a Chassis-group Member:
MX9116N-A1# show smartfabric cluster
------------------------------------
----------------------
CLUSTER DOMAIN ID : 159
VIP :
fde1:53ba:e9a0:de14:0:5eff:fe00:1159
ROLE : BACKUP
SERVICE-TAG : MXWV011
MASTER-IPV4 : 100.69.101.170
PREFERRED-MASTER :
------------------------------------
----------------------
MX9116N-A1#
Sample output from a Chassis-group Master:
MX9116N-A2# show smartfabric cluster
------------------------------------
----------------------
CLUSTER DOMAIN ID : 159
VIP :
fde1:53ba:e9a0:de14:0:5eff:fe00:1159
ROLE : MASTER
SERVICE-TAG : MXWV122
MASTER-IPV4 : 100.69.101.170
PREFERRED-MASTER :
------------------------------------
----------------------
MX9116N-A2#
ii. On the networking switch with the ROLE as
MASTER, run the "show smartfabric cluster member"
command to get the details of all the discovered
switches in the OME Modular Chassis group. This
command output provides a reference for the
upgrade procedure.
MX9116N-A2# show smartfabric
cluster member
Service-tag IP
Address
Status Role Type
Chassis-Service-Tag Chassis-Slot
------------------------------------
------------------------------------
------------------------------------
--------------
MXWV122
fde1:53ba:e9a0:de14:2204:fff:fe20:56
c9 ONLINE MASTER MX9116n
SKYMX02 A2
MXLE103
fde1:53ba:e9a0:de14:2204:fff:fe21:ca
Getting Started with Dell EMC SmartFabric OS10
53