Connectivity Guide

The NSX controller communicates with the OS10 VTEP using the OVSDB management protocol over an Secure Sockets Layer (SSL)
connection. Establishing the communication between the controller and VTEP involves generating the SSL certicate at a VTEP and
copying the certicate to the NSX controller. After SSL authentication, a secure connection over SSL is established between the controller
and the VTEP, and the VTEP receives and processes the conguration data from the controller.
Conguration notes
Consider the following when conguring controller-provisioned VXLAN in OS10:
The network virtualization edge (NVE) source interface needs to be a Loopback interface, which must be a part of the default VRF.
NSX controller-provisioned VXLAN is not supported when the OS10 switch operates in OpenFlow-only mode.
Only one mode of VxLAN provisioning (NSX Controller or Static or BGP EVPN) is supported at a time.
OS10 switch does not send the VXLAN access port statistics to the NSX controller.
Tthe VLAN IDs of VLAN interfaces created using the OS10 CLI must be dierent from the VLAN IDs of Port-scoped VLANs created in
the NSX controller for virtual networks.
Standard Compliance
OS10 complies with the RFC5880 for Bidirectional Forwarding Detection (BFD).
Controller-provisioned VXLAN operations
Manually congure the underlay network using OS10 CLI.
The controller provisions the following:
overlay network
virtual networks, and information about the service nodes in the VTEP
access ports membership in a virtual network
762
VXLAN