Connectivity Guide

Table Of Contents
1 3ffe:501:ffff:100:201:e8ff:fe00:4c8b
000.000 ms 000.000 ms 000.000 ms
View diagnostics
View system diagnostic information using show commands. Use the show hash-algorithm command to view the current hash
algorithms conīš€gured for link aggregation group (LAG) and electronic commerce messaging protocol (ECMP).
View environment
OS10# show environment
Unit State Temperature
-------------------------------------
1 up 43
Thermal sensors
Unit Sensor-Id Sensor-name Temperature
------------------------------------------------------------------------------
1 1 CPU On-Board temp sensor 32
1 2 Switch board temp sensor 28
1 3 System Inlet Ambient-1 temp sensor 27
1 4 System Inlet Ambient-2 temp sensor 25
1 5 System Inlet Ambient-3 temp sensor 26
1 6 Switch board 2 temp sensor 31
1 7 Switch board 3 temp sensor 41
1 8 NPU temp sensor 43
View hash algorithm
OS10# show hash-algorithm
LagAlgo - CRC EcmpAlgo - CRC
View inventory
OS10# show inventory
Product : S6010-ON
Description : S6010-ON 32x40GbE QSFP+ Interface Module
Software version : 10.4.2.0
Unit Type Part Number Rev Piece Part ID Svc Tag Exprs Svc
Code
------------------------------------------------------------------------------------------------
-
* 1 S6010-ON 01YRKK X01 CN-01YRKK-28298-712-0068 3601XC2 689 323 392 2
1 S6010-ON-PWR-2-AC 0AIBCD A00 TW-012345-DELTA-XXX-ABCD
1 S6010-ON-FANTRAY-1 0N7MH8 X01 04-01---
1 S6010-ON-FANTRAY-2 0N7MH8 X01 04-02---
1 S6010-ON-FANTRAY-3 0N7MH8 X01 04-03---
1 S6010-ON-FANTRAY-4 0N7MH8 X01 04-04---
1 S6010-ON-FANTRAY-5 0N7MH8 X01 04-05---
View system information
OS10#show system
Node Id : 1
MAC : 34:17:18:19:20:21
Number of MACs : 0
Up Time : 1 week 4 days 08:08:17
-- Unit 1 --
Status : up
System Identifier : 1
Down Reason :
940
Troubleshoot OS10