Concept Guide
Table Of Contents
- Dell EMC SmartFabric Services User Guide Release 1.0
- About this guide
- SFS fundamentals
- Setting up SFS
- Deploying and managing a fabric
- Access fabric setup options
- Update default fabric, switch names, and descriptions
- Create uplink for external network connectivity
- Breakout switch ports
- Configure jump host
- Update network configuration
- Onboard a server onto the fabric
- Edit default fabric settings
- Restore fabric configuration
- Manage network profiles
- Manage routing profiles
- Access fabric setup options
- SFS with VxRail
- SFS with PowerEdge MX
- SFS for Isilon/PowerScale back-end fabric
- SFS commands
- smartfabric l3fabric enable
- smartfabric vlti
- show logging smartfabric
- show smartfabric cluster
- show smartfabric cluster member
- show smartfabric configured-server
- show smartfabric configured-server configured-server-interface
- show smartfabric details
- show smartfabric discovered-server
- show smartfabric discovered-server discovered-server-interface
- show smartfabric networks
- show smartfabric nodes
- show smartfabric personality
- show smartfabric uplinks
- show smartfabric upgrade-status
- show smartfabric validation-errors
- show switch-operating-mode
- Appendix
Recommended Action:Make sure that the VLTi cables are connected
to the correct ports as per the selected fabric design.
Timestamp : 1587488570
Problem Link
SourceNode :HRA0028
SourceInterface :HRA0028:ethernet1/1/38
DestinatioNode :HRA0027
DestinationInterface:
Recommended Link
SourceNode :HRA0028
SourceInterface :HRA0028:ethernet1/1/38
DestinatioNode :HRA0027
DestinationInterface:HRA0027:ethernet1/1/38
----------------------------------------------------------
----------------------------------------------------------
ErrorKey : 8ca24343-c819-4d0b-ab12-2b9d99a36079-ISL-
[ICL-2_REVERSE]-NotFound-Issue
MessageID :
Description : Unable to validate the SmartFabric because
the VLTi cable for link ICL-2_REVERSE is not connected as per
fabric design 2xMX5108n_Ethernet_Switches_in_same_chassis.
EEMI : NFAB0012
Category : FABRIC_ERROR
Subcategory : ISL_ERROR
Severity : SEVERITY_1
Recommended Action:Make sure that the VLTi cables are connected
to the correct ports as per the selected fabric design.
Timestamp : 1587490907
Problem Link
SourceNode :HRA0038
SourceInterface :HRA0038:ethernet1/1/9
DestinatioNode :HRA0037
DestinationInterface:
Recommended Link
SourceNode :HRA0038
SourceInterface :HRA0038:ethernet1/1/9
DestinatioNode :HRA0037
DestinationInterface:HRA0037:ethernet1/1/9
----------------------------------------------------------
Supported
Releases
● MX9116n and MX5108n—10.5.0.1 or later
● SFS-supported OS10 switches—10.5.0.3 or later
show switch-operating-mode
Displays the current operating mode of a switch.
Syntax
show switch-operating-mode
Parameters None
Command Mode EXEC
Usage
Information
Some OS10 switches operate in both Full Switch and SFS modes. Use this command to view or verify the
operating mode of a switch that is deployed in the SFS environment.
Example
OS10# show switch-operating-mode
Switch-Operating-Mode : SmartFabric Mode
Supported
Releases
10.4.0E(R3S) or later