Specications
This section lists the S4100–ON Series system specications.
CAUTION: Operate the product at an ambient temperature not higher than 113°F—45°C.
CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same
or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
Chassis physical design
Table 1. Chassis physical design
Parameter Specications
Height 1.73 inches (44 mm)
Width 17.1 inches (434 mm)
Depth
18.2 inches (462 mm)
Handle: 1.57 inches (40 mm)
Chassis weight with factory-installed components
19 lbs (2* PSUs)
8.62 kg (2* PSUs)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 2. Environmental parameters
Parameter Specications
Operating temperature 5° to 40°C (50°F to 104°F) continuously
-5°C to 45°C (23°F to 113°F) short term
Short term is </= 1% of operational hours per year.
NOTE: Reduce maximum temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity 5% to 85% (RH), non-condensing, continuously
5% to 90% (RH), non-condensing, short term
Short term is </= 1% of operational hours per year.
Storage temperature –40° to 65°C (–40° to 149°F )
Storage humidity 5% to 95%, non-condensing