Setup Guide
Table Of Contents
- Dell Networking S4100-ON Series Set-Up Guide
- About this guide
- Site preparations
- S4100–ON Series installation
- Unpack the system
- Unpack
- Rack or cabinet installation
- ReadyRails installation
- 1U Tool-less mount installation
- Two-post flush-mount installation
- Two-post center-mount installation
- Four-post threaded installation
- S4100-ON Series system installation
- 1U front-rack installation
- Optics installation
- Optics removal
- System power-up
- After system installation
- Specifications
- Dell support
![](/manual/dell/powerswitch-s4128f-on-s4128t-on/setup-guide-english/images/img-20.png)
Parameter Specications
Maximum thermal output 600 W = 2047 BTU/Hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock SV0115 — ODM
Table 3. AC power requirements
Parameter Specications
Power supply 100–240 VAC 50/60 Hz
Maximum current draw per system 6A/5A at 100/120V AC 3A/2.5A at 200/240V AC
Maximum power consumption 600 Watts
Typical power consumption 300 Watts
Table 4. DC power requirements
Parameter Specications
Minimum and maximum input voltage range −40.5, –60V DC, 15A Max
Maximum Input current −40.5V/15A, −48V/12.5A, −60V/10A (without fan)
Start up VDC 39.0 ± 1.5 V
Start o VDC 37.5 ±1.5 V
20 Specications