Specifications

Table Of Contents
a Boot into the DIAG OS.
b Log in as root.
Password: calvin.
c Install the EDA-DIAG tools package.
d Run /opt/dellemc/diag/bin/edatool.
NOTE: To return to your networking operating software, enter the reboot command.
Diagnostic test suite
After the system boots up, select the EDA-DIAG option to run the diagnostic test suite.
To select which entry is highlighted, use the up and down arrow keys. Press Enter to select an operating software-selected OS or enter e
to edit the commands before booting. Enter c for a command line. The highlighted entry, displaying *, executes automatically in the
operating system.
GNU GRUB version 2.02~beta2+e4a1fe391
+---------------------------+
|ONIE: Install OS |
|ONIE: Rescue |
|ONIE: Uninstall OS |
|ONIE: Update ONIE |
|ONIE: Embed ONIE |
|*EDA-DIAG |
| |
| |
| |
+---------------------------+
View DIAG versions
To display the DIAG version installed in the DIAG OS, use the dpkg -l | grep dn-diags command at the root@dell-diag-os:~
prompt.
root@dellemc-diag-os:~# dpkg -l | grep dn-diags
ii dn-diags-<platform>-on.deb 3.xx.4.1-x amd64 Dell Networking Diagnostics
View CPLD versions
To view CPLD data, including the fan status, PSU status, current programmed version, and image packed version, use the
cpldupgradetool or updatetool command at the prompt.
For the cpldupgradetool command:
root@dell-diag-os:/# cpldupgradetool --cpldver
CPLD1 Version 0x00
CPLD2 Version 0x01
CPLD3 Version 0x01
CPLD4 Version 0x01
root@dell-diag-os:/#
For the updatetool command:
root@dellemc-diag-od~#updatetool --device_version --dev=CPU_CPLD
CPU_CPLD version:
System CPLD Version : offset 0x00 = 0xc
7: 4 Major Revision = 0
3: 0 Minor Revision = c
Scratch Register : offset 0x01 = 0x0
22
Dell EMC DIAG OS