API Guide

Source: Node.1-Unit.1
Name: EQM_THERMAL_WARN_CROSSED
Description:
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example
(Critical)
OS10# show alarms severity critical
Active-alarm details - 0
-------------------------------------------
Sequence Number: 1
Severity: critical
Type: 1081367
Source: Node.1-Unit.1
Name: EQM_THERMAL_CRIT_CROSSED
Description:
Raise-time: Sat 10-06-2018 0:1:5
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: raised
Example (Minor)
NOS# show alarms severity minor
Active-alarm details - 1
-------------------------------------------
Sequence Number: 4
Severity: minor
Type: 1081375
Source: /psu/1
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Sun 10-07-2018 18:39:47
Ack-time: Sun 10-07-2018 20:39:47
New: true
State: acknowledged
-------------------------------------------
Supported
Releases
10.4.3 or later
show alarms summary
Displays the summary of all active alarms.
Syntax
show alarms summary
Parameters None
Default Not configured
Command Mode EXEC
Usage
Information
None
Example
OS10# show alarms summary
Active-alarm Summary
-------------------------------------------
Total-count: 2
Critical-count: 0
Major-count: 1
Minor-count: 1
Warning-count: 0
-------------------------------------------
1444 Troubleshoot Dell EMC SmartFabric OS10