Reference Guide

Usage Information Congure the aging time allowed for monitored iSCSI sessions on TCP ports before the session closes. The no
version of this command disables the aging time.
Example
OS10(config)# iscsi aging time 30
Supported Releases 10.3.0E or later
iscsi enable
Enables iSCSI auto-detection of attached storage arrays and switch auto-conguration.
Syntax
iscsi enable
Parameter None
Default Enabled on S4048T-ON/S4048-ON; disabled on others
Command Mode CONFIGURATION
Usage Information iSCSI optimization automatically detects storage arrays and auto-congures switch ports with the iSCSI
parameters received from a connected device. The no version of this command disables iSCSI auto-detection.
Example
OS10(config)# iscsi enable
Supported Releases 10.3.0E or later
iscsi priority-bits
Resets the priority bitmap advertised in iSCSI application TLVs.
Syntax
iscsi priority-bits {priority-bitmap}
Parameter priority-bitmap — Enter a bitmap value for the dot1p priority advertised for iSCSI trac in iSCSI application
TLVs (0x1 to 0x).
Default 0x10 (dot1p 4)
Command Mode CONFIGURATION
Usage Information iSCSI trac uses dot1p priority 4 in frame headers by default. Use this command to recongure the dot1p-priority
bits advertised in iSCSI application TLVs. Enter only one dot1p-bitmap value — setting more than one bitmap value
with this command is not supported. The default dot1p 4 value is advertised only if you enabled PFC pause frames
for dot1p 4 trac (pfc-cos dot1p-priority command). The no version of this command resets to the
default value.
Example
OS10(config)# iscsi priority-bits 0x20
Supported Releases 10.3.0E or later
iscsi prole-storage
Congures a port for direct connection to a storage device that is not automatically detected by iSCSI.
Syntax
iscsi profile-storage storage-device-name
Parameter storage-device-name — Enter a user-dened name of a storage array that iSCSI does not automatically
detect.
Converged data center services 563