View system information
OS10# show system
System Information
--------------------------------------------
Node Id: 1
MAC: ec:f4:bb:fc:66:a3
Number of MACs: 129
Vendor: DELL
Product: S6000-ON
-- Stack --
Unit Status Up time Down Reason
--------------------------------------------
1 up
-- Power Supplies --
PSU-ID Status PowerType AirFlow Fan Speed(rpm) Status
-----------------------------------------------------
1 up AC NORMAL 1 19872 fail
2 up AC NORMAL 1 19552 up
-- Fan Status --
FanTray Status AirFlow Fan Speed(rpm) Status
--------------------------------------------
1 up NORMAL 1 18037 up
2 18037 up
2 up NORMAL 1 18078 up
2 18037 up
3 up NORMAL 1 18037 up
2 17996 up
Diagnostic commands
location-led interface
Changes the location LED of the interface.
Syntax
location-led interface ethernet {chassis/slot/port[:subport]} {on | off}
Parameters
chassis/slot/port[:subport] — Enter the ethernet interface number.
on | off — Set the interface LED to be on or o.
Default Not congured
Command Mode EXEC
Usage Information Use the location-led interface command to change the location LED for the specied interface.
Example
OS10# location-led interface ethernet 1/1/1 on
OS10# location-led interface ethernet 1/1/1 off
Supported Releases 10.3.0E or later
588 Troubleshoot OS10